UPPCL Sanctioned Load Calculator 2026-27

List your equipment, mark what runs together, and get a planning load to compare with your sanctioned load.

Connected Load • Peak Use • Planning Load

Used for the indicative fixed charge.
 

If you know your highest past usage, enter it.

As shown on your bill.

Estimated Result

 
 

Equipment list

 
 

Overview

About UPPCL Sanctioned Load Calculator 2026-27

Are you going to add an AC or water pump or any other high power appliance? First, check your sanctioned load. If your new appliance pushes your usage past what UPPCL has approved, you could face a penalty. Not because your wiring is faulty, but because your connection was never cleared for that much power.

You can calculate your sanctioned load by using this calculator.

Terms

Sanctioned Load vs Connected Load vs Maximum Demand

Your bill uses three terms that mean different things. Here’s a quick guide to what each one actually means.

Three load terms
TermWhat It MeansWho Measures ItAffects
Connected LoadTotal wattage if every appliance ran at the same timeYou, when you applyThe starting point for your calculation
Sanctioned LoadWhat UPPCL actually approves for your connectionUPPCLYour fixed charges and phase type
Maximum DemandThe highest load your meter actually recordsYour meterPenalty risk if it goes past your sanctioned load

Most domestic electricity bills in Uttar Pradesh include two components:

a fixed charge based on your sanctioned load, and an energy charge based on how much electricity you actually use.

Maximum demand is a separate matter that mainly applies to consumers with demand-recording meters, so it doesn’t affect every household the same way.

If you use more power than your sanctioned load allows, you might get charged extra. UPPCL could also ask you to increase your load limit to match what you’re actually using.

Steps

How to Calculate a Planning Load

1

1. List Equipment

Type the total number of each device and the exact wattage from its label.

2

2. Mark Peak Use

Identify which devices you usually run at the same time. If you know your highest past power usage, be sure to enter that too.

3

3. Review Result

Choose a planning margin, compare the estimate against your currently approved load, and discuss any changes with UPPCL.

Formulas

Sanctioned Load Calculation Formulas

Connected Load (kW) = Sum of (Quantity × Rated Watts) ÷ 1,000

Planning Load (kW) = Higher of Estimated Simultaneous Peak or Recorded Peak × (1 + Planning Margin)

We’ll round your result up to the nearest 0.5 or 1 kW. This is just an estimate for your planning. It doesn’t replace the actual contracted-load calculation under the current supply code, or UPPCL’s own technical assessment.

Example

A Simple Example

Let’s say your home has just four things: 2 fans, 1 fridge, and 1 AC (1.5 Ton).

Step 1: Find Your Connected Load

Connected load example
EquipmentQuantityWatts EachTotal
Fan260 W120 W
Refrigerator1250 W250 W
AC, 1.5 Ton12,200 W2,200 W

Add it all up: 120 + 250 + 2,200 = 2,570 W

Divide by 1,000 to get kW: 2,570 ÷ 1,000 = 2.57 kW

This is your Connected Load, what your home would draw if everything ran at once.

Step 2: Estimate What Actually Runs Together

In real life, do your fans, fridge, and AC all run together?

Usually, yes, these are fairly normal to run together. So your estimated peak stays close to 2.57 kW.

Step 3: Add a Planning Margin

To be safe, add a 15% margin for comfort:

2.57 × 1.15 = 2.96 kW

Step 4: Round It Off

Round up to the nearest half-kW: 3 kW

That’s your planning load, the number you could reasonably request or compare against your current sanctioned load when talking to UPPCL.

Reference

Typical Reference Appliance Wattages

These average numbers will give you a good starting point for your connected load. Just know that your exact power needs will change based on the specific brand and size of your home devices.

Typical reference appliance wattages
ApplianceTypical Power RatingImportant Note
Ceiling Fan60–80 WCheck the motor’s rated wattage.
Refrigerator150–300 WCompressor starting demand may be higher.
Air Cooler150–300 WCheck the actual model rating.
Washing Machine400–800 WPower demand varies by model and operating mode.
Water Geyser1,500–3,000 WCheck the heater’s rated power.
1-Ton AC900–1,500 WUse rated input power, not cooling capacity.
1.5-Ton AC1,200–2,200 WInverter models may vary considerably.
Water Pump370–1,100 WMotor capacity and starting demand affect requirements.
Induction Cooktop1,200–2,000 WUse the appliance’s rated input power.
UPS/Inverter ChargingVaries by modelInclude charging demand where relevant.

Keep these helpful tips in mind for your calculation:

Planning

How Much Sanctioned Load Do You Actually Need?

Your required sanctioned load comes down to three things:

The ranges below are rough planning estimates to get you started. Please remember they are not official UPPCL rules.

Suggested load for initial planning
Household TypeSuggested Load for Initial Planning
1BHK with basic appliances1–2 kW
2BHK with an AC and geyser3–5 kW
Independent house with multiple ACs and heavy appliances6–10 kW

Why choosing the right load matters

Treat the table above as a starting point. From there, work out your actual connected load using the real wattage of your appliances. Before you apply for a new connection or a load enhancement, check the current UPPCL tariff and connection requirements for your category.

Phase

Single-Phase or Three-Phase: Which Do You Need?

Single-phase supply can only handle so much before voltage stability becomes a problem. Past a certain point, UPPCL shifts you to three-phase supply instead.

Single-phase and three-phase
Supply TypeTypical Use CaseNotes
Single-PhaseStandard homes, lower loadLower deposit, simpler wiring
Three-PhaseHeavy appliance use, higher loadDifferent wiring and deposit requirements

Does UPPCL have a mandatory load threshold?

Here is what you need to know about the 10 kW limit:

Penalty

What Happens If You Exceed Your Sanctioned Load?

Your smart meter tracks your highest power usage. If that peak goes over your sanctioned load, you could face extra charges. This applies to domestic users with demand-recording meters. If you keep crossing the limit, UPPCL may increase your sanctioned load on their own.

If your power needs have genuinely grown, it is better to apply for a load enhancement yourself. Check your latest bill and the current UPPCL tariff to see exactly what charges apply to your connection.

Apply

How to Apply for a UPPCL Load Enhancement

1

Keep your consumer number and latest bill ready.

2

List the new appliances or changes that raise your power needs.

3

Apply online. Log in to the official UPPCL Consumer Portal and select “Load Enhancement.”

4

Upload your documents. Follow the portal steps to submit any required details, extra documents, or fees.

5

Schedule and fees for inspections. As per your new load, UPPCL may ask for site visit and some additional charges or small electrical modifications.

6

Track your progress. Check the portal for status updates and follow any instructions from your local DISCOM until the work is done.

Important:

The exact documents, fees, and timeline depend on your specific connection and current rules. Always check the latest instructions on the official portal before you start.

Contact

Need to Change Your Sanctioned Load? Here's Who to Contact

Whether you’re applying for a new connection or increasing the sanctioned load on an existing connection, UPPCL provides online services and customer support to guide you through the process.

FAQ

Frequently Asked Questions

No. Connected load is the theoretical total of everything you own. Sanctioned load is what UPPCL actually approves, and it’s usually lower.

Yes. Diversity rules exist precisely because nobody runs every appliance at once.

Not quite. “Ton” refers to cooling capacity, not how much power the unit draws. Most 1.5-ton ACs use somewhere between 1.2 and 1.8 kW, depending on the star rating.

No. Units measure energy used over time. Sanctioned load measures capacity at any given moment. They’re answering two different questions.

Not just from the extra capacity alone, but your fixed charges might shift depending on your tariff category.

Expect a penalty. And if it keeps happening, that’s a sign you need a load enhancement, not a smaller appliance list.

It gives you a solid estimate. The final call on phase type comes from UPPCL once they review your sanctioned load.

Look at your electricity bill, or check your connection details on the UPPCL portal.

kW is the actual power doing the work. kVA includes some extra reactive power in the mix. For most homes, the difference barely matters, but industrial connections sometimes need kVA specifically.

Explore

More Calculators

Uttar Pradesh Electricity Bill

Estimate your Uttar Pradesh electricity bill using FY 2026-27 tariff rates for domestic, rural, Life Line/BPL, commercial, institutional, agricultural and other UPPCL categories.

Electricity Bill Unit Rate Calculator

Find the effective electricity rate per unit from your bill, or estimate electricity charges from units and a known rate.

BWSSB Water Bill Calculator

Bengaluru water and sanitary charges for homes, apartments and non-domestic use

PVVNL Bill Calculator

Estimate your Pashchimanchal Vidyut Vitran Nigam Limited (PVVNL) electricity bill using FY 2026-27 Uttar Pradesh tariff rates.

DVVNL Bill Calculator

Estimate your Dakshinanchal Vidyut Vitran Nigam Limited (DVVNL) electricity bill using FY 2026-27 Uttar Pradesh tariff rates.

KESCO Bill Calculator

Estimate your Kanpur Electricity Supply Company Limited (KESCO) electricity bill using FY 2026-27 Uttar Pradesh tariff rates.

PuVVNL Bill Calculator

Estimate your Purvanchal Vidyut Vitaran Nigam Limited (PuVVNL) electricity bill using FY 2026-27 Uttar Pradesh tariff rates.

Delhi Jal Board Bill Calculator

Estimate a Delhi Jal Board domestic or commercial water bill using the tariff rates shown below.

MVVNL Bill Calculator

Estimate your Madhyanchal Vidyut Vitran Nigam Limited (MVVNL) electricity bill using FY 2026-27 Uttar Pradesh tariff rates

KWA Water Bill Calculator

Estimate Kerala Water Authority water charges using the latest tariff currently published by KWA.

Power Consumption Calculator

Enter the power rating and daily hours to find the energy use in kWh and the running cost of your appliances.

UPPCL Meter Reading Calculator

Add the previous and current readings from your meter to find the units you used. Estimating your bill is optional.

UPPCL Solar Net Metering Calculator

Find what you will pay once your solar export is adjusted against grid import.

Scroll to Top